A rigid, closed-cell inorganic insulation made from pure glass. Non-combustible, zero water absorption, and dimensionally stable across the full cryogenic range. Specified for LNG tank bottoms, tank walls, cryogenic piping and equipment where fire safety and moisture resistance cannot be compromised.
| Material | Closed-cell cellular glass, pure glass, no asbestos |
|---|---|
| Density grades | 120 / 130 / 140 / 150 / 160 / 220 kg/m³ |
| Thermal conductivity | 0.043 – 0.056 W/(m·K) at 25 °C mean |
| Compressive strength | 0.80 – 2.40 MPa (ASTM C165) |
| Service temperature | -268 °C to +480 °C |
| Water absorption | ≤ 0.5 vol% (ASTM C240) |
| Fire performance | Non-combustible, flame spread ≤ 5 (ASTM E84) |
| Standard board | 610 × 460 mm, thickness 160 / 180 / 200 mm |
Higher density carries more load: use CG120–140 for pipe and wall insulation, CG150–220 for tank bottom bearing layers. Custom sizes and curved segments are cut to drawing.
| Property | CG120 | CG130 | CG140 | CG150 | CG160 | CG220 |
|---|---|---|---|---|---|---|
| Density, kg/m³ | 120 ±8% | 130 ±8% | 140 ±8% | 150 ±10% | 160 ±10% | 220 ±15% |
| Thermal conductivity, W/(m·K) | 0.043 | 0.044 | 0.046 | 0.047 | 0.048 | 0.056 |
| Compressive strength, MPa | 0.80 | 1.00 | 1.20 | 1.40 | 1.60 | 2.40 |
| Flexural strength, MPa | ≥ 0.31 | ≥ 0.35 | ≥ 0.40 | ≥ 0.46 | ≥ 0.50 | ≥ 0.53 |
| Water absorption, vol% | ≤ 0.5 (ASTM C240) | |||||
| Vapour permeability, Ng/(Pa·m·s) | ≤ 0.007 (ASTM E96) | |||||
| Flame spread index | ≤ 5 (ASTM E84) | |||||
| Service temperature, °C | -268 to +480 | |||||
Test methods: ASTM C303, C177, C165, C203, E96, C240, E84. Batch test reports and third-party inspection certificates issued per shipment on request.
Tank diameter, wall thickness, bottom area, service temperature and destination port are enough for us to return a technical proposal with quantity take-off and price.